Al-Nahrain Journal for Engineering Sciences
Login
NJES
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Submission Resources
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
  • Policies
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Copyright Policy
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Abstracting and Indexing
    • Announcements
    • Contact

Search Results for A. M. Takhakh

Article
Investigate the Microstructure and the Mechanical Properties of Ni-Ti-Cu Shape Memory Alloys

Dania F. Abbas Aljuboori, Kadhim K. Resan, Ayad M. Takhakh

Pages: 105-112

PDF Full Text
Abstract

In this study a Nickel-Titanium-Cupper shape memory alloys was manufactured by powder metallurgy (PM) technique, powder mixture of 50% Ti , 47% Ni and 3% Cu was prepared by mixing for two hours and compacted in a press machine using various compacting pressure (600, 700 and 800) MPa , sample was then sintered for 5 hrs in an electrical tube vacuum furnace using sintering temperature of (850?C, 900?C and 950?C) .phase analysis of samples was conducted by X-ray diffraction test, the effect of different sintering temperature and compacting pressure on the porosity, microhardness ,compression strength and the shape memory effect (SME) was studied, the result showed decrease in the porosity and increasing in the shape recovery ,compression strength and microhardness with increasing compacting pressure and at lower sintering temperature and hence the best results was at 800MPa compacting pressure and 850?C sintering temperature.

Article
Performance Evaluation of Gesture Recognition Using Myo Armband and Gyroscope Sensors

S. M. Sarhan, M. Z. Al-Faiz, A. M. Takhakh

Pages: 461-468

PDF Full Text
Abstract

The technique of recording muscle signals is crucial in determining how effectively they can be utilized for individual benefit. This study focuses on hand movements recognized by using the Myo armband and Motion Processing Unit (MPU) 6050 sensors. Linear Discriminant Analysis (LDA), K-nearest neighbors (k-NN), and Support Vector Machine (SVM) were employed for classification. sEMG signals using the Myo armband for 7 hand gestures and 2 elbow movements were recorded from 10 healthy subjects. Results showed that SVM outperforms LDA and k-NN in accuracy in both cases, the sensor is worn once on the arm and again on the forearm. regions. The window size and choice of features significantly influence system accuracy, with SVM achieving an average accuracy of 89.84%. Besides that, the fusion of Myo Armband sensor and gyroscope sensor through OR rule makes significant enhancement in recognition accuracy with which is reached to 97.0135%. In conclusion, the Myo armband, when worn on the forearm, proves practical for hand gesture recognition, with SVM offering superior recognition accuracy. Furthermore, the combination of the Myo Armband sensor and the gyroscope sensor showed higher recognition accuracy.

Article
Microstructure and Compressive Peak Stress Analyses of 3D Printed TPU MM-3520

Ahmed Ameen, Ayad Takhakh, Abdalla Abdal-hay

Pages: 336-345

PDF Full Text
Abstract

Specimens with the structure of a face-centered cubic were produced using several sets of printing conditions. An experimental testing is conducted to carefully evaluate the microstructural analysis and compressive strength of this structure. The results include the measurement of mechanical properties, such as the peak stress. Fused deposition modeling is employed for the additive manufacturing of experimental specimens made from shape memory polymer thermoplastic polyurethane (MM-3520). We take into account the impact of printing factors on lattice structures, such as layer thickness, printing temperature, and printing speed. Analyzing the microstructure of the printed specimens exhibits that the specimens with highest printing temperature, lowest printing speed and thinner printing layer have better layers adhesion and lower porosities. All the mechanical tests are performed on specimens with the same structure and at a relatively constant density. Among the tested printing parameters, using a layer height of 0.1 mm, a printing temperature of 230 °C, and a printing speed of 20 mm/s yields the highest strength in the specimens. However, specimens printed with a layer height of 0.2 mm, a printing temperature of 220 °C, and a printing speed of 30 mm/s also exhibit good strength, albeit slightly lower than the maximum values. Additionally, when using these specific settings (0.3 mm – 210 °C – 40 mm/s), the mechanical qualities are minimized, yet the stress-strain curves exhibit characteristics similar to elastomers.

Article
An Overview of Functional Gradient Biomaterials Manufacturing Process of Implants Types

Nawzad K. Khalil, Ayad, M. Takhakh, Abdalla Abdul-Hay Ali

Pages: 169-184

PDF Full Text
Abstract

Functionally graded material is one of the promising sectors of the material since because of the great ability to control with required product properties could be strongly used in biomedical applications exclusively in the implants sector, this review paper demonstrates briefly about the most prominent known manufacturing methods and focusing on the implants coated by FGM layer manufactured by using EPD method because the EPD has significant properties it could produce FGM layer in the Room temperature without depending on chemical reactions or heat adding, Biomedical application need highly accuracy when we deal with material that directly contact with human tissue because the heat effect could be change the biocompatibility properties and also the chemical reactions could make toxic effect on the produced implants, All these reasons make the EPD one of the favorable method for the FGM coated Implants. this paper will summarise and give the Gide line for the researcher about the most important substrate and suspension materials used in the EPD method and its application.

Article
Review of Exploring the Future of Prosthetics Using Osseointegration Technology

Saif M. Abbas, Ayad M. Takhakh, Jumaa S. Chiad

Pages: 186-197

PDF Full Text
Abstract

Additionally, it has been demonstrated that osseointegrated implantation offers superior proprioception and control over the prosthesis, enabling more natural movement and improved functional results. Additionally, it lowers the chance of falling and increases energy transfer efficiency, making it simpler for amputees to engage in physical activity. Furthermore, as compared to conventional socket prosthesis attachment, osseointegrated implantation has been linked to higher patient satisfaction and quality of life._x000D_ It is crucial to remember that osseointegration is a surgical operation with risks including infection and implant failure. Additionally, for effective implantation, it needs a specific amount and quality of bone, which may restrict its usage in some individuals. Furthermore, osseointegrated implantation could be more expensive than conventional socket prosthetics._x000D_ Understanding the efficacy and safety of this method requires research on complication rates and outcome metrics in patients having osseointegrated prosthesis implantation. You may acquire information on things like infection rates, implant failure, patient satisfaction, and functional results by studying original research papers. Clinical decision-making can then be improved with the use of this information._x000D_ In transfemoral amputees, osseointegration has showed promise as a powerful substitute for socket prostheses. A growing corpus of research has shown that osseointegrated implantation provides advantages in terms of increasing mobility, decreasing discomfort, and improving general quality of life. The efficiency of osseointegration for transtibial and upper extremity implants has received little attention._x000D_ Minor soft tissue infections are the most frequent consequences, although they are manageable with the right treatment and monitoring. To further reduce the risk of problems and improve the overall success of osseointegrated implantation, research and development are ongoingly focused on enhancing surgical methods and implant design._x000D_ Although osseointegration has a lot of potential, not all amputees may be good candidates for it. Considerations for osseointegrated implantation must take into consideration elements including the degree and nature of the amputation, the quality and density of the bone, and the desires of the patient.

Article
Optimization of Friction Stir Spot Welding Parameters of Al6061T6 by Hybrid Approached

Rasha Mohammed Hussein, Sameh Fareed Hasan, Ayad M. Takhakh, Mohsin Abdullah Al-Shammari

Pages: 131-137

PDF Full Text
Abstract

The most important way for joining the non-welding aluminum alloy is Friction stir spot welding. Three parameters effect on efficiency of welding: tool shape, rotational speed, and plunged time, are chosen to study for welding 6061T6 aluminum alloy. Each of the above parameters has three variables as: pin shapes (square, cylinder, and hexagonal), plunged time (50, 70,100) sec  and rotational speeds (710, 1120, 1800) rpm hybrid approach which is consist of the experiment run, neural network and social spider optimization is used to optimize the welding conditions by finding the maximum ultimate force. The best condition of the weldments is (square, 710rpm, 100sec) with maximum shear force 4740N. The best results obtained from hybrid optimization with experimental results; with discrepancy of 2%.

Article
Mechanical Properties of Hybrid and Polymer Matrix Composites That Used To Manufacture Partial Foot Prosthetic

Hassanein Salih Hussain, Ayad Murad Takhakh

Pages: 887-893

PDF Full Text
Abstract

In this study, an experimental comparison has been made between the traditional plastic materials (Polypropylene and Polyethylene) and selected composite materials (Perlon-Carbon-Perlon and Hybrid Carbon fiber-Glass fiber) to manufacture a long life Partial Foot Prosthesis. To improve the mechanical properties, increase the lifetime of the prosthesis, and reduce the cost to the patient, two types of composite materials were used and compared with plastic materials. Samples were manufactured and tested with different test methods (Tensile, flexural, and fatigue test). All tests were performed at room temperature.The results showed that the composite materials achieve a large increment in mechanical properties such as (?y, ?ult, E, ?b, and Ef) whichwere increased to a percentage of (200% - 261%),(330% - 243%), (295% - 203%), (276% - 270%),and (413% - 301%) in Perlon-Carbon-Perlonlamination as compared with Polypropylene andPolyethylene respectively. However theincreasing percentage in Hybrid Carbon fiber-Glass fiber was (353% - 270%), (470% - 347%),(388% - 267%), (203% - 199%), and (244% -178%) as compared with Polypropylene andPolyethylene. At the same time, the fatigue lifewas sharply increased in both of the Perlon-Carbon-Perlon and Hybrid Carbon fiber-Glassfiber.

1 - 7 of 7 items

Search Parameters

×

The submission system is temporarily under maintenance. Please send your manuscripts to

Go to Editorial Manager
Journal Logo
Al-Nahrain Journal for Engineering Sciences (NJES)

College of Engineering, Al-Nahrain University

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY NC 4.0 Logo Licensed under CC-BY-NC-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

Copyright © 2026 College of Engineering, Al-Nahrain University, its licensors, and contributors. All rights reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.