Al-Nahrain Journal for Engineering Sciences
Login
NJES
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Submission Resources
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
  • Policies
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Copyright Policy
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Abstracting and Indexing
    • Announcements
    • Contact

Search Results for Ahmed A. Alammar

Article
Manufacturing and Testing Pneumatic Pads Adjustable Socket for A Below-Knee Prosthetic

Ammar Issam Salih Kubba, Ahmed A. Alammar

Pages: 164-168

PDF Full Text
Abstract

The purpose of this research is to manufacture and test adjustable sockets for below-knee amputation. This article studies using the pnuematic–pads for adjustable sockets. The manufacturing of an adjustable socket with pneumatic pads goes through several stages: In the theoretical design of the adjustable socket, the suggested materials were studied for the pneumatic pads, tubes, and pneumatic pump which should be suitable for the suggested application. In the experimental work, using composite materials for manufacturing the socket consisting of perlon and resin to achieve the rigid shape and required flexibility for the prosthetic user with the pneumatic pads. After assembling the adjustable socket parts, the pneumatic pads, the pump and the tubes, the socket were tested for several times on the patient. In the last stage, the pressure between the socket and the residual limb was measured using F-socket, and it was found that the results were: anterior (160kPa), lateral (167kPa), posterior (153kPa) and medial (348kPa). By comparing these results with what was previously studied, the pressure between the socket and the residual limb is within the acceptable range. The design provides good suspension and more adaptability to the change in stump volume. A posative feedback was given by the patient who used the prosthetic patient for several days as a trial to measure its safety and comfortablty.

1 - 1 of 1 items

Search Parameters

×

The submission system is temporarily under maintenance. Please send your manuscripts to

Go to Editorial Manager
Journal Logo
Al-Nahrain Journal for Engineering Sciences (NJES)

College of Engineering, Al-Nahrain University

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY NC 4.0 Logo Licensed under CC-BY-NC-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

Copyright © 2026 College of Engineering, Al-Nahrain University, its licensors, and contributors. All rights reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.