Go to Editorial ManagerThe purpose of this research is to manufacture and test adjustable sockets for below-knee amputation. This article studies using the pnuematic–pads for adjustable sockets. The manufacturing of an adjustable socket with pneumatic pads goes through several stages: In the theoretical design of the adjustable socket, the suggested materials were studied for the pneumatic pads, tubes, and pneumatic pump which should be suitable for the suggested application. In the experimental work, using composite materials for manufacturing the socket consisting of perlon and resin to achieve the rigid shape and required flexibility for the prosthetic user with the pneumatic pads. After assembling the adjustable socket parts, the pneumatic pads, the pump and the tubes, the socket were tested for several times on the patient. In the last stage, the pressure between the socket and the residual limb was measured using F-socket, and it was found that the results were: anterior (160kPa), lateral (167kPa), posterior (153kPa) and medial (348kPa). By comparing these results with what was previously studied, the pressure between the socket and the residual limb is within the acceptable range. The design provides good suspension and more adaptability to the change in stump volume. A posative feedback was given by the patient who used the prosthetic patient for several days as a trial to measure its safety and comfortablty.
This article is about studying the placing direction effect of a piezoelectric sensor on the shoe insole in the GRF results. Where the sensors used in this research are in two directions, along and perpendicular to the foot midline. In the both cases the sensors were fixed on the shoe insole to sense the foot pressure. For the first set of sensors which are perpendicular to the foot midline the collected data has similar trend to the GRF collected from the force plate, as the small lateral strain in the shoe insole due to the patient weight and GRF is close to the GRF data collected from other measurement system. On the other hand, the collected data from the second set of sensors which are in a longitudinal direction with the foot midline will have different trend and values from the collected data from the force plate or any other GRF measurement system. This different in the results is due to the large longitudinal strain in the shoe insole due to the patient weight which produce dissimilar results from the force plate result data.