×
The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerMany difficulties were recorded during laser-assisted tattoo removal. But most of them remain unknown. The recent literatures on laser tattoo removal focuses more on removal methods and systems than on side effects, such as temperature increase over tissue and ideal treatment parameters. This study aims to assess the surface temperature in compliance with eyebrow tattoo removal. The study was carried out for 55 patients aged between 22 and 43 years. The treatment was performed using a Nd:YAG laser (1064nm, Phi laser system) with an energy of 1000 mJ, a frequency of 3Hz, and a spot size of 8mm. The surface temperature of the skin during tattoo removal process was measured with a FLIR thermal camera. The results were analyzed by testing the normal state of distribution. The Shapiro-Wilk and Kolmogorov-Smirnov tests were used. All patients finished the full treatment of three laser sessions to achieve the goal of total removal. After temperature comparison, the results showed a significant influence of skin nature and patients' age on temperature distribution on skin, as for older patients, the energy absorption increased. Additionally, patients with darker skin tones exhibited greater absorption. The benefit of deepening understanding appeared in the Temperature distribution in the tissues of the affected area and the surrounding area during laser irradiation, as it provides a guiding and reference function for the effect of photothermal therapy.
This research focuses on enhancing the diagnostic power of the slit lamp, a fundamental ophthalmic instrument, by replacing its traditional halogen light source with a cutting-edge white laser. The objective of this modification is to significantly improve the brightness, intensity, and color accuracy, which are crucial for distinguishing fine ocular details during eye examinations. White laser technology offers a more stable, energy-efficient light source with reduced maintenance needs, making it a valuable upgrade over conventional systems. As part of this redesign, the optical system will be optimized with new filters, lenses, and heat management techniques to accommodate the white laser. Additionally, integrating a high-resolution digital camera with the enhanced illumination system is expected to provide sharper, more accurate imaging for better diagnosis. The anticipated outcome is a transformative improvement in ocular diagnostics, leading to earlier and more precise detection of eye conditions. This advancement holds promise for both patients, through better care, and ophthalmologists, through increased diagnostic efficiency. Challenges in implementation and potential solutions are also considered.
An experimental study on single bubble breakage in the stirred tank in oil as a continuous phase was carried out for a range of stirring speeds (220 to 430 rpm). The results are compared with bubble breakage in water that was conducted by Hasan et al. (2021) to investigate the effect of physical properties of continuous phase on the breakage rate. The breakage events in the impeller were captured and analyzed using a high speed camera. It was found that the breakage rate represented by breakage probability and a number of produced daughter bubbles (fragments) are directly proportional with the stirring speed. The breakage probability and number of produced daughter bubbles in oil was noticeably lower than that in water indicating the role the continuous phase viscosity plays in reducing the breakage rate.
A proposed modern technique for determination the blood group typing by monitoring the agglutination of red blood cells using acousto-optical technique and digital camera. The method based on analysis the digital image of the agglutination process by MATLAB software._x000D_ We present an overview of two acousto-optic sensing approaches; the first demonstrates the cuvette approach while the second is the microscope slide approach. The cuvette approach digital image analyzing depends on the green channel distribution of the original image and count the brighten pixels, while the microscope slide approach passes through series of algorithms started with grayscale filter and end with edge detection it counts the different color pixels._x000D_ The experimental result shown that it is possible to enhance the determination of blood group typing by using acousto-optical technique in both cases of using isohemagglutinating sera as well as the crossmatch test in a short time and high efficiency compared with the traditional methods.
Gait analysis can be described as a field of biomechanical engineering dealing with the subject of human locomotion. This study aimed to identify the effect of Ilizarov on gait when the presence the above-knee prosthesis. The study was made on a 50-year-old male patient was underwent correction right tibia with Ilizarov fixation due to war accident in July 2012. Also, this accident led to trans-femoral amputation. Two-dimensional gait system of a synchronized 25 Hz camera with an AMTI force platform was use for measuring gait kinematics and kinetics data while walking at a self-selected speed. These data can be used as standard measures in pathology studies, as input to theoretical joint models, and as input to mechanical joint simulators treated with Ilizarov and prosthetics.