The submission system is temporarily under maintenance. Please send your manuscripts to
Go to Editorial ManagerForced vibration has been experimentally investigated on a model consists of circular pipe with1.6m length. The pipe built in tank (1.2m length, 0.6m height and 0.6m width) horizontally at 0.4m height with two different diameters d=15mm and d=35mm. The pipe conveying laminar flow in the fully developed region, of Reynolds number equals 2000. The experimental results of span pipe conveying water at five stations of forced excitation vibration were studied. The harmonic forced vibration with two different excitation frequencies (10 Hz and 15 Hz) are imposed at all of the five locations. The distance between two stations is (0.2m). Two conditions of pipe environment have been applied, the first in air and the other was immersed in water. It is concluded that the effect of flow induced vibration due to the pipe conveying fluid increases the maximum deflection when the fluid speed increases. The water surrounds the pipes reduce the effect of excitation vibration about (33 – 46%). The effect difference between the excitation frequencies was about (4 – 7%).
The present work is a numerical study of thermal performance of modified flat plate solar water collectors. Numerical simulations have been done by solving the governing equations (Continuity, Momentum and Energy) equations in the laminar regime , three dimensions by using the FLUENT software version (14.5). The effect of flow on temperature distribution of flat plate water collectors by inserting (twist strip with twist ratio (3), helical spring surrounding the solid shaft) inside riser pipes is numerically simulated and compared with solar collector without inserting device inside its riser pipes at flow rates of (100)?/h . The numerical simulation results show that the flat plate water, solar collectors with the inserted, twist strip and helical spring that’s surround the solid shaft were higher enhancement of heat transfer than without inserted devices. The useful energy in case of twist strip is (10%) higher than the case of flat plate solar collector without enhancement device. Also, the case of helical spring is increased (6.8 %) than the twist strip, and (16.2%) than collector without enhancement device for the same mass flow rate.
This research presents an experimental study of forced convection heat transfer for laminar steady flows in a duct filled with saturated porous media glass balls.The heater model consists of a circular cylinder , square cylinder and triangular cylinder .The experimental work was studied the effect of changing heater section on forced convection heat transfer with selected values of heat supply ( 2455W/m2 ).The experiments were carried out for Reynolds number ( 1094 ?
Natural convection air heat transfer and fluid movement currents around a hot circular cylinder inside an inclined triangular enclosure has been analyzed experimentally. Three different sizes of an enclosure with a long side of 20, 25, and 30 cm, the thickness of 1 mm, and depth of 50 cm were used in the present work to give three radius ratios. The effect of Rayleigh number, radius ratio, the rotation angle of triangle enclosure, and the inclination angle of the apparatus with horizontal axis ? on the heat transfer process was investigated. The ranges of these parameters were: Rayleigh number from 5×106 to 2.5×108, radius ratio (0.345, 0.455, and 0.618), rotation angle (0o, 45o, and 90o), and inclination angle (0o, 45o and 90o). The results show that the heat transfer rates increase with increase in Rayleigh number and as the rotation angle of enclosure is changed from 0o to 90o. Moreover, the heat transfer rate increases linearly with Rayleigh number at higher radius at rotation angle 0o, 90o only. While, it increases slightly with Rayleigh number at rotation angle 45o. Additionally, the higher heat transfer rates occur at vertical position of enclosure inclination angle 90o and rotation angle 0o (the base of triangle at the bottom) and it decreases as inclination angle deviates from 90o to 0o. This behavior is reverse completely at higher radius ratio 0.618. Empirical correlations for the average Nusselt number has been found to depend on Rayleigh number., radius ratio, rotation angle and inclination angle.
A numerical study was performed of natural laminar convective heat transfer to its concentrated triangular enclosure around a horizontal circular cylinder. The air-filled enclosure kept the inner and outer cylinders at uniform temperatures. The Boussinesq density approximation to the momentum problem and the control volume approach iteratively resolved the governing equations to explain buoyancy. CFD results show that the velocity behavior increases by increasing Ra, so the stream lines becomes more sluggish and less uniform behavior and vortices gets less circulated pattern. The rotation angle ? has significant effect on vortices, at 90o gives the higher range of velocity zones of free convection with higher range. The thermal boundary layer seems to be larger in rr=0.455 as compared with rr=0.345 and decreases by increasing ?. The larger variation of isotherms and thermal boundary layer appears at lower ? because the higher heat transfer rate occurs at higher ? and becomes maximum at 90o. Eight correlations of average Nusselt number have been deduced as a function of Rayleigh number for the taken values of aspect ratio and enclosure angles of rotation and inclination.
Non-dispersive near-infrared technique is widely used nowadays for the detection of gases, especially in harsh environments. In this study, an optical gas cell was designed for oxygenator exhaust capnometry. A computer-based simulation was used for the analysis of air flows for model selection. ANSYS Discovery 2020 R2 was used for model simulation. The gas flow cells were tested using a custom-made gas rig to measure the fraction absorbance of carbon dioxide gas at the detector. Two gases were used, nitrogen gas as a reference gas (0%) and 9% carbon dioxide. Three gas cells with the following optical path lengths were tested: 31mm, 36mm, and 40mm. The results showed that all gas flow cells produced laminar flow and small pressure drop across the inlet and outlet of the cell (11~12 Pa). Further, the minimum velocity is obtained in the 40mm gas flow sensor and it is located at the gas outlet path away from the effective optical gas path. The simulation and experimental results indicate that the gas flow cell of 40mm optical path length is more suitable for the intended application as it offers a maximum effective absorption path compared to the stagnation areas, and as a result, it provides the maximum fraction absorbance.