Go to Editorial ManagerThis study examines the flow behavior and lift coefficient variations of a NACA 4415 airfoil using different vortex generator configurations. Experimental investigations are conducted in a subsonic wind tunnel at a Reynolds number of 1.8 x 105. The airfoil is tested with two types of vortex generators, namely the dome vortex and the convergent-divergent vortex, positioned at 10%, 28%, and 60% chord locations. Experimental lift coefficients are compared with Airfoil Tools database, showing consistent agreement within an angle of attack range of 0 to 18 degrees. At small angles of attack (0 to 8 degrees), the lift coefficients of the NACA 4415 airfoil with the dome vortex at 10%, 28%, and 60% chord positions are lower compared to the baseline configuration. However, beyond 14 degrees, the highest lift coefficient value after the angle range of 14-18 degrees is achieved at the 60% chord position with the dome vortex, 10.43% increase compared to the baseline lift coefficient. Furthermore, the best value for the lift coefficient after the angle range of 16-18 degrees at the 10% chord position is achieved with the dome vortex, where the maximum lift coefficient 9.4% increase compared to the baseline lift coefficient. It is noted that the baseline configuration consistently outperforms the convergent-divergent vortex configurations.
Numerical and experimental investigations were carried out on the effect of the vortex generators on the flow field and heat transfer from duct heaters. The flow Reynolds number ranging from 32000<Re<83000 with a constant heat flux of 43.09426._x000D_ In the numerical investigation, Fluent package (6.3) was used to solve the steady, (3-D), continuity, momentum and energy equations where the standard (k-?) model was used to remedy the turbulent effects. Theoretical results show that the presence of VGs would save 27% of heaters power. The effects of two areas of VGs were looked at a small circle cross section vortex generator (SCCSVG) and a big circle cross section vortex generator (BCCSVG) of similar shapes (where)._x000D_ The experimental results showed that there were an enhancement in heat transfer with the presence of VGs and heat transfer depends on VGs’ areas. The BCCSVG was the better one of enhancing heat transfer by (2.76%-4.11%). Additionally, the increase of area of VGs, number of rows for VGs and the distance between each two rows of VGs and the heaters are the most effective parameters in improving the performance of heat transfer.