Al-Nahrain Journal for Engineering Sciences
Login
NJES
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Submission Resources
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
  • Policies
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Copyright Policy
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Abstracting and Indexing
    • Announcements
    • Contact

Search Results for walking

Article
A Study of the Effect of the Difference in Energy Stored in Two Prosthetic Feet Made of Carbon Fiber Amputated Below the Knee on the Efficiency of Walking

Noor Basim, Yassr Y. Kahtan

Pages: 97-108

PDF Full Text
Abstract

ESAR feet are prosthetic feet with carbon fiber parts that store mechanical energy while standing and release it during propulsion. It is believed to reduce the metabolic energy needed for walking, and to promote the economy of walking. However, there is little scientific evidence to support this claim. This study aimed to compare the energy storage properties of two prosthetic feet made of carbon fiber using the P-Walk, G-Walk, and Podium devices developed for gait analysis, which is a systematic examination of human movement, enabling phasing, estimation of musculoskeletal performance, and determination of kinematic and motor parameters. The amount of energy was calculated for each of the feet using the load deflection test, and the results showed that the new artificial foot with an energy of 6.186 joules showed a great improvement in the results of the tests compared to the old artificial foot with an energy of 3.403 joules. The Podium device tests showed a significant improvement in walking patterns and pressure distribution after using a new foot. The pressure distribution became almost equal on both sides, and the angular deviation of COP decreased from -7 to 1.3 degrees. Ground reaction force vector tilt results also improved, with a body angle of 0 degrees and inclination varying slightly depending on the tibiofemoral angle for males. P-Walk results reveal left-sided static test pressure distribution, exposing amputees to osteoarthritis risk and revealing lack of confidence in prosthetic foot. After use the new prosthetic foot, amputees press more on right foot, indicating balance restoration. The G-Walk device shows the effectiveness of both healthy left and prosthetic foot when walking on an amputated right leg when use the new prosthetic foot. The amputated side's performance is similar to a healthy limb, with minimal difference and within normal limits. Walking cadence and speed values are within normal ranges, while stride length and step length are outside normal ranges for both sides. Obliquity results show a small difference in pelvic angles due to weak pelvic muscles, but these are close to standard values for prosthetic foot use. The amputee's opinions about the evaluation of the new prosthetic foot were good when using the T-score by 61.0 with a rate of 86.4%. It was a significant improvement compared to the old foot with an evaluation of 53.6 by 63.9%.

Article
Robust Stability Control of Inverted Pendulum Model for Bipedal Walking Robot

Ali Fawzi Abdul Kareem, Ahmed Abdul Hussein Ali

Pages: 81-88

PDF Full Text
Abstract

This paper proposes robust control for three models of the linear inverted pendulum (one mass linear inverted pendulum model, two masses linear inverted pendulum model and three masses linear inverted pendulum model) which represents the upper, middle and lower body of a bipedal walking robot. The bipedal walking robot is built of light-weight and hard Aluminum sheets with 2 mm thickness. The minimum phase system and non-minimum phase system are studied and investigated for inverted pendulum models. The bipedal walking robot is programmed by Arduino microcontroller UNO. A MATLAB Simulink system is built to embrace the theoretical work. The results showed that one linear inverted pendulum is the worst performance, worst noise rejection and the worst set point tracking to the zero moment point. But two masses linear inverted pendulum models and three masses linear inverted pendulum model have a better performance, a better high-frequency noise rejection characteristic and better set-point tracking to the zero moment point.

Article
Measurement and Analysis of ground reaction forces Distribution and electromyography for Ankle Joint Fixation Injury Using Different Types of Shoes

Noora Fakhri, Jumaa S. Chiad

Pages: 358-364

PDF Full Text
Abstract

One of the health issues that many people encounter on a daily basis is bone fracture, which can happen for a number of reasons, such as arthritis, sprains, or external trauma . The patient experiences instability as a result of these issues . Internal fixation is a type of surgery used to support and mend a damaged bone Treatment options include ankle joint fixation, a surgical procedure employing pins, plates, rods, or screws. This study uses gait analysis methods to assess lower limb biomechanics .  Gait analysis is vital for understanding walking patterns and intervention effectiveness. The impact of different shoe designs on ankle mechanics, using the finite element method and ANSYS, is investigated The results of the EMG and the GRF were discussed._x000D_ This research deepens our understanding of lower limb biomechanics and ankle joint health. By evaluating stress effects and designing custom shoes, it enhances ankle injury treatment and management strategies._x000D_ The patient, a 70-year-old woman with an internal fixation on her ankle joint, underwent a CT scan of her ankle. The patient underwent a number of experiments to evaluate her stability. EMG was used to determine the muscle stress for a brief period of time, and ground reaction force was then used to determine the pressure of walking. Both EMG and GRF have two walking speeds of1.5and 2 km/h while wearing four different types of shoes. The behavior of the EMG demonstrates that the stress on the muscle increases as walking speed increases, and the results varies depending on the shoe. The patient is afraid to apply pressure to the injured foot, so the health foot has better pressure over the entire foot_x000D_  

Article
Metabolic Cost Reduction and Analysis of Assisted Walking Gait: A Review

Noor Abdul Kareem Shehab, Mahmud Rasheed Ismail

Pages: 392-402

PDF Full Text
Abstract

With the occurrence of pathological disorders in some people or aging, metabolic energy consumption begins significantly due to the weakness of the peripheral muscles and the increase in body fat with time, which aggravates the issues for this type of people, causing the rest hours extremely lengthy and consequently may produce heart or arterial diseases and elevate the mortality rate. Regarding the significance of the matter, this study examines a number of previous researches that featured several approaches to energy calculation and strategies for lowering energy consumption through the use of various external assistance devices, such as exosuits or exoskeletons, to assist people in carrying out their everyday tasks. And additionally discussed musculoskeletal simulation employs a variety of programs, especially OpenSim, which enables users to build models of musculoskeletal structures and produce dynamic movement simulations. According to the research findings, exoskeletons and other assistive technology can successfully lower the cost of metabolic energy to varying extents, depending on the device's weight, placement within the body, and whether it is active, semi-active, or inactive. In the future, the work to design and simulate a semi-active torsional ankle-foot exoskeleton with a specialized mechanism aimed to minimize metabolic energy.

Article
Stress Analysis of Thoracolumbosacral Orthosis (TLSO) for Scoliosis deformity and its Effects on Gait Cycle

Fahad Mohanad Kadhim, Sara I. Ahmed

Pages: 187-193

PDF Full Text
Abstract

This work involved two major parts: the first one is the experimental part which included treatment of scoliosis deformity by manufacturing thoracolumbosacral orthosis, measuring  the cobb angle of deformity, measuring the gait cycle data and walk path for both legs and suggesting a composite material to improve the mechanical properties of the orthosis and finally the interface pressure between trunk  and orthosis is measured for twelve points covering of the total TLSO surface area by using f-socket devise. The second part of this study is the numerical simulation part during which the stresses are calculated using Ansys software for calculating stresses due to interface pressure loading boundary condition. The result shows no deference in gait cycle phases but the clear difference noted in walking path due to deviate center of mass, maximum pressure recorded left thoracic region with 900KPa due to correct spinal deformity while the minimum pressure recorded at right chest with l40KPa because of it is tissue region and Maximum value of stress was recorded at the left thoracic region with 2.81MPa due to Maximum interface pressure at this point.

Article
Compare Between Gait Analysis of Patient with Ilizarov Leg and Prosthesis Leg

Omyia Mahmoud Jawad, Sadiq Jaffar Abass, Safa Kadiam Dia’a

Pages: 178-186

PDF Full Text
Abstract

Gait analysis can be described as a field of biomechanical engineering dealing with the subject of human locomotion. This study aimed to identify the effect of Ilizarov on gait when the presence the above-knee prosthesis. The study was made on a 50-year-old male patient was underwent correction right tibia with Ilizarov fixation due to war accident in July 2012. Also, this accident led to trans-femoral amputation. Two-dimensional gait system of a synchronized 25 Hz camera with an AMTI force platform was use for measuring gait kinematics and kinetics data while walking at a self-selected speed. These data can be used as standard measures in pathology studies, as input to theoretical joint models, and as input to mechanical joint simulators treated with Ilizarov and prosthetics.

1 - 6 of 6 items

Search Parameters

×

The submission system is temporarily under maintenance. Please send your manuscripts to

Go to Editorial Manager
Journal Logo
Al-Nahrain Journal for Engineering Sciences (NJES)

College of Engineering, Al-Nahrain University

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY NC 4.0 Logo Licensed under CC-BY-NC-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

Copyright © 2026 College of Engineering, Al-Nahrain University, its licensors, and contributors. All rights reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.